Technical Information Watt Density for Typical Applications vs. TemperatureRise
Density Watts / Square Foot Desired Comfort Temperature Rise ˚F
Application
Condition
5°F
10°F
15°F
20°F
25°F
I ndoor Supplementry Heat Indoor Personnel Comfort Indoor Personnel Comfort Indoor Personnel Comfort Indoor Personnel Comfort
15 to 30 Watts / Square Foot
No Drafts/No Cold Walls Average Conditions Drafty Are/Cold Walls
5 to 6 11 to 13 17 to 20 22 to 26 28 to 33 7 to 9 15 to 18 23 to 28 30 to 36 39 to 47 10 to 12 20 to 24 30 to 36 40 to 48 50 to 60
Large Mall Type Buildings Removal and Control Protected Area W/Wind Shield
40 TO 60 WATTS / SQUARE FOOT 15 TO 30 WATTS / SQUARE FOOT 80 TO 120 WATTS / SQUARE FOOT
Indoor Moisture
Outdoor Loading Dock Outdoor Marquee Heating
Snow & Ice Melting Use Table B 20 ft. Mounting Hgt.
TECHNICAL
Outdoor Personnel Comfort
Not Open To Sky
10 to 12 20 to 24 30 to 36 40 to 48 50 to 60
Protected Area No Wind Radiant Fixtures for spot heating of individuals should be mounted 10 to 12 feet from the floor with coverage from at least two (2) sides and directed at the individuals waist and never directly overhead. If fixture must be mounted over 12' from the floor, add 25% to the indicated watt density up to a maximum of 15'. SnowControl DesignGuidelines
Outside Design Temperature (˚F)
Annual Snowfall
Exposed* w/ sq.ft.
Semi-Protected*
Protected*
Inches
w/ sq.ft.
w/ sq.ft.
-20 to -60 -20 to -60 -20 to -60 -20 to -60 -20 to -60 -10 to -19 -10 to -19 -10 to -19 -10 to -19 -10 to -19 0 to -9 0 to -9 0 to -9 0 to -9 0 to -9 19 to 1 19 to 1 19 to 1 19 to 1 19 to 1 40 to 18 40 to 18 40 to 18 40 to 18 40 to 18
80 to 115 50 to 79 20 to 49 10 to 19 80 to 115 50 to 79 20 to 49 10 to 19 80 to 115 50 to 79 20 to 49 10 to 19 80 to 115 50 to79 20 to 49 10 to 19 80 to 115 50 to 79 20 to 49 10 to 19 0 to 9 0 to 9 0 to 9 0 to 9
200 175 125 110 100 175 125 110 100 100 125 110 100 100 100 110 100 100 100 100 100 100 100 100 100
185 160 110 100 160 110 100 90
160 145 100
90 85
145 100
90 85 75 90 85 75 65 90 85 75 65 60 60 60 60 60 60
90 80
110 100
100
90 80 70 90 80 70 70 70 70 70 70 70
100
0 to 9
Heater Selection Guidelines 1. Always use clear quartz lamps as the correct element selection 2. Use CRDS or CRTS stainless steel enclosures for outdoor locations 3. For best results use 30˚ symmetric units. 60˚ symmetric or assymetric enclosures are generally satisfactory in semi-protected or shielded areas. Never use 90˚ reflectors.
* Exposed = Totally open area * Semi-Protected = One side closed plus roof or overhang * Protected = Three sides plus roof or overhang